Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1687977 | Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms | 2006 | 9 Pages |
Abstract
Measurements of the stopping forces for 14C, 14N and 16O ions in Ge and Au, for 14N and 19F ions in Ag, as well as for 19F ions in Au have been made, respectively. A novel technique, reported recently, using PIN diodes coated directly with the stopping medium in a polka dot pattern was used. This provided a set of precise, self-consistent measurements on the same stopping medium. Results show small but significant deviations from SRIM stopping predictions and are also compared to a recently-developed empirical stopping force predictor.
Related Topics
Physical Sciences and Engineering
Materials Science
Surfaces, Coatings and Films
Authors
T.D.M. Weijers-Dall, H. Timmers, K. Stenström, P. Persson, A. Pergjegjaj, X. Wang, M. Graczyk, T. Osipowicz, M.Q. Ren, D.J. O’Connor, H.J. Whitlow,