Abstract
⺠Permalloy (Ni-Fe-Mo) alloy and ferritic (Fe-Cr) stainless steel were selected for the vacuum chambers with high magnetic permeability. âºÂ Outgassing rate of permalloy alloy with vacuum heat treatment is 1 · 10â8 Pa m/s. ⺠Magnetic annealing at a temperature higher than 850 °C is effective for the magnetic shielding. âºÂ Heat treatment under high vacuum condition can be used as both magnetic annealing and outgassing reduction.
Related Topics
Physical Sciences and Engineering
Materials Science
Surfaces, Coatings and Films
Authors
J. Kamiya, N. Ogiwara, M. Nishikawa, Y. Hikichi, T. Yanagibashi, M. Kinsho,