Article ID Journal Published Year Pages File Type
1728926 Annals of Nuclear Energy 2012 6 Pages PDF
Abstract

The Unprotected Loss-of-Flow (ULOF) transient and the Unprotected Transient-Over-Power (UTOP) have been evaluated for the European Lead-cooled SYstem (ELSY) for americium concentrations in the fuel between 0% and 10%. With americium in the core, the ELSY design exceeds the maximum allowed asymptotic temperature limit for fuel during UTOP, except for low Am contents. During ULOF, fuel and clad temperatures stabilize below the asymptotic temperature limits.

► Reference ELSY design is not suitable for Am burning. ► During ULOF at ELSY with up to 10% Am temperatures stabilize below maximal limits. ► During UTOP fuel temperature exceeds the limits for more than 1.5% Am.

Keywords
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,