To obtain gamma and neutron attenuation characteristics experimental measurements and Monte Carlo simulations were carried out for hematite-loaded concrete samples. Also, the mechanical strength of samples was studied. However, the results for neutron attenuation reveal that there is no effect of hematite inclusion in concrete with respect to the neutron absorption capability. Gamma-ray attenuation capability and the mechanical strength both increased with increasing the hematite percent.

► Gamma and neutron shielding measurements and simulations were performed for hematite loaded new concrete samples. ► Hematite percentage were increased step by step. ► When hematite mineral is add to concrete, the gamma radiation shielding capability of concrete increases. ► Neutron attenuation capability of concrete is unaffected by hematite additive.

Related Topics