Article ID Journal Published Year Pages File Type
1729242 Annals of Nuclear Energy 2011 8 Pages PDF
Abstract

Hydrogen safety has attracted extensive concern in severe accident analysis especially after the Fukushima accident. In this study, a similar station blackout as happened in Fukushima accident is simulated for CPR1000 nuclear power plant (NPP) model, with the computational fluid dynamic code GASFLOW. The hydrogen risk is analyzed with the assessment of efficiency of passive autocatalytic recombiner (PAR) system. The numerical results show that the CPR1000 containment may be damaged by global flame acceleration (FA) and local detonation caused by hydrogen combustion if no hydrogen mitigation system (HMS) is applied. A new condensation model is developed and validated in this study for the consideration of natural circulation flow pattern and presence of non-condensable gases. The new condensation model is more conservative in hydrogen risk evaluation than the current model in some compartments, giving earlier starting time of deflagration to detonation transition (DDT). The results also indicate that the PAR system installed in CPR1000 could prevent the occurrence of the FA and DDT. Therefore, HMS such as PAR system is suggested to be applied in NPPs to avoid the radioactive leak caused by containment failure.

► We analyze the hydrogen risk in CPR1000 during station blackout with GASFLOW code. ► Hydrogen detonation likely occurs during the accident. ► Application of PAR system could eliminate the hydrogen risk. ► The condensation model with McAdams correlation performs better in validation work. ► It predicts the hydrogen risk conservatively in some compartments.

Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,