The regional overpower protection (ROP) systems protect CANDU® reactors against overpower in the fuel that would reduce the safety margin-to-dryout. Both a localized power peaking within the core (for example, as a result of certain reactivity device configuration) or a general increase in the core power level during a slow-loss-of-regulation (SLOR) event could cause overpower in the fuel. This overpower could lead to fuel sheath dryout. In the CANDU® 600 MW (CANDU 6) design, there are two ROP systems in the core, one for each fast-acting shutdown systems. Each ROP system includes a number of fast-responding, self-powered flux detectors suitably distributed throughout the core within vertical and horizontal assemblies. Traditionally, the placement of these detectors was done using a method called the detector layout optimization (DLO). A new methodology for designing the detector layout for the ROP system has been developed recently. The new method, called the DETPLASA algorithm, utilizes the simulated annealing (SA) technique to optimize the placement of the detectors in the core. Both methodologies will be discussed in detail in this paper. Numerical examples are employed to better illustrate how each method works. Results from some sensitivity studies on three SA parameters are also presented.