Article ID Journal Published Year Pages File Type
1730066 Annals of Nuclear Energy 2008 4 Pages PDF
Abstract
The reactor cold start-up is a process of inserting reactivity by lifting control rod discontinuously. Inserting too much reactivity will cause short-period and may cause an overpressure accident in the primary loop. It is therefore very important to understand the rule of neutron density variation and to find out the relationships among the speed of lifting control rod, and the duration and speed of neutron density response. It is also helpful for the operators to grasp the rule in order to avoid a start-up accident. This paper starts with one-group delayed neutron point-reactor kinetics equations and provides their analytic solution when reactivity is introduced by lifting control rods discontinuously. The analytic expression is validated by comparison with practical data. It is shown that the analytic solution agrees well with numerical solution. Using this analytical solution, the relationships among neutron density response with the speed of lifting control rod and its duration are also studied. By comparing the results with those under the condition of step inserted reactivity, useful conclusions are drawn.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,