Article ID Journal Published Year Pages File Type
1732715 Energy 2014 6 Pages PDF
Abstract
In this paper, thermodynamic calculations of nozzle governing stage are taken based on APROS (Advanced Process Simulation), and verify through the comparison of experiment table data. The influence of partial admission on pressure ratio within the governing stage is also analyzed. The results show that partial admission not only leads to partial admission losses, but also makes an impact on pressure ratio, enthalpy and reaction degree, in turn, causes the change of efficiency. Then, the nozzle pressure ratio after the full-open valve and semi-open valve respectively, is expressed as a function of flow ratio based on dimensional analysis. This paper presents a method of thermodynamic calculation for nozzle governing stage. Comparing with the results calculated through APROS and discussing the change of pressure ratio and reaction degree, it shows that the method can reflect the influence of partial admission on pressure ratio exactly, and further improve the accuracy of existing thermodynamic calculation.
Related Topics
Physical Sciences and Engineering Energy Energy (General)
Authors
, , , ,