•Only a few experimental studies reported in the literature on oil free scroll expander.•This paper shows performance measurement (isentropic efficiency, shaft power) of a small scale oil free expander.•A performance map of the expander is generated using measurements.•The use of oil free scroll expander in CHP system is considered.
The present paper focuses on the experimental characterization of an open-drive scroll expander integrated into an Organic Rankine cycle using R245fa as working fluid. The expander is a commercially available air compressor that was modified to operate in expander mode. The ORC (Organic Rankine Cycle) system is designed for a nominal heat input of 20 kW and a nominal net power output of 1.8 kW. A total of 74 steady-state operating points are measured to evaluate the expander performance over a wide range of conditions. The operating parameters that are varied include the inlet pressure (from 9 to 12 bar), outlet pressure (from 1.5 to 4 bar) and rotational speed (from 2000 to 3500 rpm). The maximum isentropic efficiency and shaft power are, respectively, 75.7% and 2.1 kW. A maximum cycle efficiency of 8.5% is reached for evaporating and condensing temperatures of 97.5 °C and 26.6 °C respectively. For most of the tests, hot water is produced in the condenser and the system therefore behaves as a CHP (combined heat and power). Depending on the water temperature requirement, a power to heat ratio varying between 1.9% and 11.8% is obtained. Water over 50 °C can be produced with a power to heat ratio higher than 8%.The experimental data points are then used to generate a performance map of the expander. This performance map allows for simulation of the use of such an expander in other ORC system.