This paper presents a mathematical model of six-phase synchronous generator (SPSG) for analysis of its transient and dynamic behavior for stand-alone renewable energy generation in conjunction with a hydro power plant. In the analytical model, effect of common mutual leakage reactance between the two three-phase winding sets, and the mutual leakage coupling between d- and q-axis of the two stator windings have been considered. Paper also discusses the applicability of SPSG for supplying two individual loads by presenting the results of analytical and experimental study of transient and steady-state behavior under various operating conditions. It is shown that it can be used to supply two independent three-phase loads. While the interaction between the two windings is inevitable and variation of load at one winding set changes the operating conditions at the other winding, the situation is still satisfactory for a wide range of rural resistive loads.

► Analytical model developed for six-phase generator is very simple and unified. ► Six-phase synchronous generator possesses more power to weight ratio. ► Six-phase synchronous generator offers better voltage and frequency regulation. ► Six-phase synchronous generator can deliver power to two independent customers. ► Six-phase synchronous generator offers improved reliability of power supply.