Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1735296 | Energy | 2010 | 9 Pages |
Abstract
Thermo vapor compressor (TVC) is simply a steam ejector employed in multi-effect desalination (MED) system. A greater understanding of flow phenomena inside an ejector is important for improving ejector performance. We conducted a computational fluid dynamics (CFD) investigation into the flow structure inside a steam ejector. The study focused on the effects of operating pressure and ejector geometry on the flow structure and performance of the steam ejector. The CFD results were verified with available experimental data. The angle of the converging duct considered the geometrical parameter in this study was varied as 0, 0.5, 1, 2, 3.5 and 4.5°. The ejector with a converging duct angle of 1° has the best performance.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Energy (General)
Authors
MyoungKuk Ji, Tony Utomo, JuSik Woo, YongHun Lee, HyoMin Jeong, HanShik Chung,