Article ID Journal Published Year Pages File Type
1738889 Journal of Environmental Radioactivity 2009 5 Pages PDF
Abstract

In this paper deposition rate coefficients for unattached and attached radon progeny were estimated according to a particle deposition model for turbulent indoor airflow described by Zhao and Wu [2006. Modeling particle deposition from fully developed turbulent flow in ventilation duct. Atmos. Environ. 40, 457–466]. The parameter which characterizes turbulent indoor airflow in this model is friction velocity, u*. Indoor ventilation changes indoor airflow and friction velocity and influences deposition rate coefficients. Correlation between deposition and ventilation rate coefficients in the room was determined. It was shown that deposition rate coefficient increases with ventilation rate coefficient and that these parameters of the Jacobi room model cannot be assumed to be independent. The values of deposition rate coefficients were presented as functions of friction velocity and ventilation rate coefficient. If ventilation rate coefficient varies from 0.1 up to 1 h−1, deposition rate coefficients for unattached and attached fractions were estimated to be in the range 3–110 h−1 and 0.015–0.35 h−1, respectively.

Related Topics
Physical Sciences and Engineering Energy Nuclear Energy and Engineering