This technical note provides some considerations for the metallographic observation of intergranular attack (IGA) in Alloy 600 steam generator tubes. The IGA region was crazed along the grain boundaries through a deformation by an applied stress. The direction and extent of the crazing depended on those of the applied stress. It was found that an IGA defect can be misevaluated as a stress corrosion crack. Therefore, special caution should be taken during the destructive examination of the pulled-out tubes from operating steam generators.