Abstract
The demands for fresh process waters and heating/cooling utilities arise intermittently in batch plants. Due to equipment constraints, the quality and flow-rate of each resulting wastewater stream are required to be controlled within specified limits before treatment/regeneration. In this paper, a general mathematical programming model is developed to design the optimal buffer system for equalizing the flow-rates and contaminant concentrations of its outputs. Three examples are provided to illustrate the effectiveness of proposed approach.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Chemical Engineering (General)
Authors
Chuei-Tin Chang, Bao-Hong Li,