Article ID Journal Published Year Pages File Type
1741511 Progress in Nuclear Energy 2006 10 Pages PDF
Abstract

The VVER-1000 Coolant Transient Benchmark consists of two phases and refers to experimental data from the Kozloduy Unit 6 Nuclear Power Plant in Bulgaria. The paper describes the modelling features and their impact on the results of the Exercise 1, Phase 1 of the Benchmark obtained by two ATHLET user groups, namely GRS and NRI. The simulated transient is a main coolant pump (MCP) switching on in one loop at reduced power while three other MCPs are in operation. Particular attention is paid to the influence of the reactor vessel modelling and especially of the nodalization in the upper plenum. The comparison and discussion of the two simulation results confirm that the two solutions with the ATHLET system code achieve quite good system response of the plant transient.

Keywords
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , , ,