Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1759737 | Ultrasonics | 2010 | 5 Pages |
Abstract
This work addresses three key subjects to the image quality with phased arrays: timing accuracy, beamforming strategy and post-processing for increased resolution and suppression of grating and side lobes.Timing accuracy is achieved by defining a modular and scalable architecture which guarantees low timing errors, whatever is the system size. The proposed beamforming methodology follows the progressive focusing correction technique, which keeps low focusing errors, provides a high information density and has a simple implementation for real-time imaging in modular architectures. Then, phase coherence imaging is defined to suppress grating and sidelobe indications, simultaneously increasing the lateral resolution.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Acoustics and Ultrasonics
Authors
C. Fritsch, J. Camacho, M. Parrilla,