Abstract
A tumor-mapping algorithm was proposed to identify the same regions in different passes of automated breast ultrasound (ABUS). A total of 53 abnormal passes with 41 biopsy-proven tumors and 13 normal passes were collected. After computer-aided tumor detection, a mapping pair was composed of a detected region in one pass and another region in another pass. Location criteria, including the radial position as on a clock, the relative distance and the distance to the nipple, were used to extract mapping pairs with close regions. Quantitative intensity, morphology, texture and location features were then combined in a classifier for further classification. The performance of the classifier achieved a mapping rate of 80.39% (41/51), with an error rate of 5.97% (4/67). The trade-offs between the mapping and error rates were evaluated, and Az = 0.9094 was obtained. The proposed tumor-mapping algorithm was capable of automatically providing location correspondence information that would be helpful in reviews of ABUS examinations.