Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1767252 | Advances in Space Research | 2010 | 5 Pages |
Abstract
We have installed the first MAGDAS magnetometer at Fayum in Egypt. The ambient temperature in the initial sensor house varied more than ±4 °C in one day (24 h period). This variation made the magnetic data useless. To correct this problem, (1) a new sensor house was re-constructed which reduced the diurnal variation to less than ±1 °C, and (2) the “Uozumi Temperature Correction Method” was introduced. As a result, good data is now arriving in real time at a central facility in Japan.
Keywords
Related Topics
Physical Sciences and Engineering
Earth and Planetary Sciences
Space and Planetary Science
Authors
A. Mahrous, E. Ghamry, R. Elhawary, I. Fathy, Y. Yamazaki, S. Abe, T. Uozumi, K. Yumoto,