Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1767802 | Advances in Space Research | 2007 | 7 Pages |
Abstract
Integral data on the exposure due to non-neutron and neutron-like component obtained on the base of MDU and calculated data are compared with the data obtained by TLDs and TEDs, respectively. Total effective dose during the period mentioned (494 flights and 2940Â h between taking offs and landings) was found to be about 11-12Â mSv for. Results obtained by means of different approaches are analyzed and discussed, it was found that in general good agreement of all data sets could be stated.
Keywords
Related Topics
Physical Sciences and Engineering
Earth and Planetary Sciences
Space and Planetary Science
Authors
F. Spurný, O. Ploc, I. JadrnÃÄková, K. Turek, T. Dachev, M. Gelev,