Article ID Journal Published Year Pages File Type
1801239 Journal of Magnetism and Magnetic Materials 2010 7 Pages PDF
Abstract

In this study, the signal-to-noise ratio (SNR) performances of longitudinally, randomly, and perpendicularly oriented particles, based on hexagonal barium ferrite (h-BaFe) platelets with an average volume of 2400 nm3 have been studied as a function of the recording head to media distance by numerical micromagnetic simulations. The distances from the write head to media and from the read head to media were varied independently. For a fixed read distance and varied writing distances, the SNR was decreasing in larger write distance. An optimum write distance of 40 and 50 nm was found for the longitudinally oriented media and the perpendicularly oriented media, respectively. The optimum write distance for longitudinally oriented media, 40 nm, resulted in the local minimum SNR for the perpendicularly oriented media. In most write distances the perpendicularly oriented media show the outstanding best performance, but near the write distance of 40 nm the longitudinally oriented media work as good as the perpendicularly oriented media. In a fixed write distance with various read distances, the SNR was almost constant in each media whereas the average signal amplitude was exponentially decayed in larger read head to media distance. The best SNR was found in the perpendicularly oriented media at write head to media distance dwrite=20 nm and read head to media distance dread=40 nm. The best SNR value is 11.9 and 24.4 dB in time domain and frequency domain, respectively.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Condensed Matter Physics
Authors
, , , , , ,