Abstract
Local anodization on a permalloy (Ni80Fe20) thin film by an atomic force microscope (AFM) in air was studied. Fabrication of uniform structure on the permalloy film was difficult in comparison with that on a Si(1 0 0) substrate. On the permalloy film, threshold voltage for the AFM anodization increased until 3 h after exposure to air. With passage of time, I-V curves on the permalloy film also changed from metallic behavior to insulating one. In addition, I-V curves varied at positions on the permalloy film. The oxide layer with time- and position-dependencies can induce non-uniform structure in AFM anodization. However, uniformity of structure was able to be improved by using method of fabrication of dots.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Condensed Matter Physics