Article ID Journal Published Year Pages File Type
1804645 Journal of Magnetism and Magnetic Materials 2007 6 Pages PDF
Abstract
Influence of the magnetizing and pick-up conditions on the optimum magnetic descriptors of magnetic adaptive testing (MAT) was studied by measuring a series of cold-rolled austenitic stainless steel samples. It was found that the way of magnetization and of picking-up the signal had no qualitative influence on relative values of the descriptors.
Related Topics
Physical Sciences and Engineering Physics and Astronomy Condensed Matter Physics
Authors
, , ,