Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1810592 | Physica B: Condensed Matter | 2012 | 4 Pages |
Abstract
In this present work, the minor hysteresis loops model based on parameters scaling of the modified Jiles–Atherton model is evaluated by using judicious expressions. These expressions give the minor hysteresis loops parameters as a function of the major hysteresis loop ones. They have exponential form and are obtained by parameters identification using the stochastic optimization method “simulated annealing”. The main parameters influencing the data fitting are three parameters, the pinning parameter k, the mean filed parameter α and the parameter which characterizes the shape of anhysteretic magnetization curve a. To validate this model, calculated minor hysteresis loops are compared with measured ones and good agreements are obtained.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Condensed Matter Physics
Authors
M. Hamimid, S.M. Mimoune, M. Feliachi,