Article ID Journal Published Year Pages File Type
1822012 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2016 5 Pages PDF
Abstract

We developed a new real-time radiation sensor using an organic semiconductor and measured its β-particle detection sensitivity. This sensor is fabricated by simply combining a p-type semiconductor, polyaniline (Pani), with an n-type semiconductor, TiO2, and processing the compound. Since Pani and TiO2 are both inexpensive materials, the sensor can be fabricated at a lower cost than inorganic semiconductor sensors. The signal of each fabricated sensor was measured by a charge sensitive ADC for the irradiation of β-particles. The response signal data of the ADC for each irradiation was measured to calculate the detection efficiency of the detector. The maximum detection efficiency measured as β-particle sensitivity of the sensor was 1%. This β-particle sensitivity is higher than that reported of Pani sensors in the past.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , , , , , ,