Article ID Journal Published Year Pages File Type
1822298 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2015 10 Pages PDF
Abstract

This paper presents the design and implementation of the front-end electronics and the data acquisition (DAQ) system for readout of multi-wire drift chambers (MWDC). Apart of the conventional drift time measurement the system delivers the hit position along the wire utilizing the charge division technique. The system consists of preamplifiers, and analog and digital boards sending data to a back-end computer via an Ethernet interface. The data logging software formats the received data and enables an easy access to the data analysis software. The use of specially designed preamplifiers and peak detectors allows the charge-division readout of the low resistance signal wire. The implication of the charge-division circuitry onto the drift time measurement was studied and the overall performance of the electronic system was evaluated in dedicated off-line tests.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , , , ,