Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1822621 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2014 | 8 Pages |
Abstract
Development of the plastic scintillator with neutron sensitivity from thermal to multi-MeV and pulse shape discrimination (PSD) has been demonstrated. Incorporation of 10B-containing compounds into the plastic scintillator with PSD capability leads to detector improvement in regard to neutron detection efficiency while preserving the discrimination between neutrons and γ-rays. Effects of boron loading on scintillation and pulse shape discrimination properties are discussed. A PSD figure-of-merit value of 1.4±0.03 has been achieved for events in a thermal neutron energy domain, 50–100 keVee, for PSD plastic loaded with 5 wt.% of m-carborane.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
I.A. Pawełczak, A.M. Glenn, H.P. Martinez, M.L. Carman, N.P. Zaitseva, S.A. Payne,