A digital method for the discrimination of neutron and γ-ray events based on analyzing the power spectra of the signals from a BC501A liquid scintillator detector was presented and investigated in this paper. In order to evaluate the feasibility of this novel pulse shape discrimination method, a 5GSample/s 8-bit oscilloscope was used to acquire waveforms for n/γ discrimination. Furthermore, the performance of this novel n/γ discrimination method was compared with that of a widely used method called the reference-pulses method which averaged a large number of neutron and γ-ray pulses to obtain the reference-pulse as the criterion for n/γ discrimination. The results showed that the proposed method performed well over the reference-pulses method, which was verified by the considerable decrease in the error rate of n/γ discrimination and the improvement of the Figure of Merit.