Abstract

A new sensor based on laser absorption spectroscopy was developed for the detection of coolant leakage which may happen in pressurized heavy water reactor (PHWR). Off-axis integrated output spectroscopy (OA-ICOS) technique was adopted for developing a simple and robust sensor with sufficient sensitivity. Leak events could be monitored by detecting a small change in semi-heavy water (HDO) concentration induced by the exchange reaction of leaked heavy water (D2O) with light water (H2O). From the results of feasibility tests, we have shown that the measured area of absorption features was linearly correlated with HDO concentration, and the minimum detectable change of HDO concentration with the developed sensor was evaluated as 3.2 ppm. This new sensor is expected to be a reliable and promising device for the detection of coolant leakage since it has some advantages on real-time monitoring and early detection for nuclear safety.