| Article ID | Journal | Published Year | Pages | File Type | 
|---|---|---|---|---|
| 1824063 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2012 | 5 Pages | 
Abstract
												The electric field inside a Resistive Plate Chamber (RPC) is likely to be influenced by the non-uniform inner surfaces of the RPC electrodes. We have studied the effect of this field perturbation on the performance of the RPC by a Monte Carlo method, which simulates the generation of signal from the detector. For the present study, we have analyzed the effect of the field variation on the time resolution and efficiency of a 0.3 mm single-gap timing RPC. Finally the results obtained from the Monte Carlo study are compared with an analytical calculation.
Keywords
												
											Related Topics
												
													Physical Sciences and Engineering
													Physics and Astronomy
													Instrumentation
												
											Authors
												Tapasi Ghosh, Subhasis Chattopadhyay, 
											