Article ID Journal Published Year Pages File Type
1826649 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2010 4 Pages PDF
Abstract

A method for evaluating the two-dimensional photon density distribution in focused hard X-ray beams is proposed and demonstrated in a synchrotron experiment at SPring-8. A synchrotron X-ray beam of 11.8 keV is focused to a ∼1μm spot by Kirkpatrick–Baez mirrors. The two-dimensional intensity distribution of the focused beam is derived by monitoring the forward diffracted intensity from an isolated silver nanocube with an edge length of ∼150nm positioned in the beam waist, which is two-dimensionally scanned. Furthermore, the photon density of X-rays illuminated onto the nanocube is estimated by utilizing coherent X-ray diffraction microscopy. This method is useful for evaluating the photon density distribution of hard X-ray beams focused to a spot size of less than a few micrometers.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , , , , , , ,