Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1828824 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2008 | 7 Pages |
Abstract
In this paper, 3D-electrode pixel detectors are described, in which the bias electrode systems have additional elements. Adding resistors between the bias supply line and each bias electrode together with a signal electrode readout that can measure pulse heights of both polarities could simultaneously provide lower capacitance and improved spatial resolution in both directions. A separate paper (“Dual-readout—strip/pixel systems”) covers an alternative—pixels with an added strip readout in one direction which could be used with either planar or 3D-electrodes, and could simultaneously provide a fast trigger and significantly increase the spatial resolution in both directions.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
Sherwood Parker, Cinzia Da Via, Mario Deile, Thor-Erik Hansen, Jasmine Hasi, Christopher Kenney, Angela Kok, Stephen Watts,