Abstract
In this paper we present some results on the radiation tolerance of the CMS forward pixel detector. They were obtained from a beam test at Fermilab of a pixel-detector module, which was previously irradiated up to a maximum dose of 45Â Mrad of protons at 200Â MeV. It is shown that CMS forward pixel detector can tolerate this radiation dose without any major deterioration of its performance.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
G.B. Cerati, M.E. Dinardo, A. Florez, S. Kwan, A. Lopez, S. Magni, S. Malvezzi, D. Menasce, L. Moroni, C.R. Newsom, D. Pedrini, M. Rovere, S. Sala, P. Tan, S. Taroni, M. Turqueti, L. Uplegger,