Abstract
3D-electrode pixel detectors are proposed in which the bias electrodes are connected to form a strip readout on the same or opposite side of the sensor. It can provide a fast trigger and significantly increase spatial resolution in both directions. This combination is also possible with double-sided processing in planar technology. A second paper (“Dual Readout—3D Direct/Induced-Signals Pixel Systems”) will cover another means of increasing spatial resolution without duplicating the complex pixel electronics.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
Cinzia Da Via, Sherwood Parker, Mario Deile, Thor-Erik Hansen, Jasmine Hasi, Christopher Kenney, Angela Kok, Stephen Watts,