Article ID Journal Published Year Pages File Type
1829699 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2008 6 Pages PDF
Abstract

Lanthanide and actinide targets are prepared at the University of Mainz by molecular plating, an electrochemical deposition from an organic solvent, for heavy-ion reaction studies at GSI. To acquire information about deposition yield, target thickness, and target homogeneity, the following analysis methods are applied.With neutron activation analysis (NAA) the deposition yield and the average thickness of the deposited material is determined. We report on the analytical procedure of NAA performed subsequent to the molecular plating process.Scanning electron microscope (SEM) is used to determine the morphology of the target surfaces. In combination with energy dispersive X-ray spectrometer (EDS), we also could obtain qualitative information about the chemical form of the deposited material. So far, gadolinium, samarium, holmium, and uranium targets have been investigated with SEM/EDS.With radiographic imaging (RI), targets of uranium prepared by molecular plating and by vacuum vaporization are investigated. This method is suitable to obtain information about the spatial distribution, the homogeneity, and the thickness of the target layer deposition.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , , , , , , , , , ,