Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1829799 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2008 | 6 Pages |
Abstract
Multi-pixel photon counters (MPPC) are pixelated Geiger-mode photon manufactured by Hamamatsu photonics. They will be used for reading out all the scintillator elements within the near detector of the T2K experiment. Their performances photo-detection efficiency, dark noise and gain, and their insensitivity to magnetic field fulfill the ND280 requirements. On the other hand, two known issues, cross-talk and after-pulsing may adversely impact the detector response. In this paper, cross-talk and after-pulsing are precisely measured by recording waveforms and identifying all the avalanche pulses. At an over-voltage of 2Â V, an avalanche generates on an average 0.5 additional avalanches due to after-pulsing, whereas it generates 0.13 at 1Â V over-voltage. After-pulses follow two independent time constants of 15 and 82Â ns. The cross-talk probability is a factor of 3 smaller than the after-puling probability. Simulating the MPPC response, we find that after-pulsing and cross-talk do not degrade the detector performance significantly within the expected operating conditions of the T2K near detector.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
Y. Du, F. Retière,