Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1829864 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2007 | 4 Pages |
Abstract
We report on first tests of Geiger-mode APDs (G-APD) to detect Cherenkov light from cosmic particle induced air showers. The motivation for this study stems from the requirement to improve the sensitivity of large imaging atmospheric Cherenkov telescopes (IACT) by replacing the photomultipliers (PMT) by high detection efficiency G-APDs. Three tests have been carried out, confirming sufficiently high light sensitivity of blue-sensitive G-APDs as future replacement of PMTs in IACTs.
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Instrumentation
Authors
A. Biland, I. Britvitch, E. Lorenz, N. Otte, F. Pauss, D. Renker, S. Ritt, U. Roeser, M. Schneebeli,