Article ID Journal Published Year Pages File Type
1830204 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2007 5 Pages PDF
Abstract

The results obtained from the activation foils measurement are unfolded using two different deconvolution methods such as BUNKI and genetic algorithm (GA). The spectra produced by these codes agree fairly with each other and are comparable with that measured previously for the same system using NE213 liquid scintillator and by unfolding the neutron-induced proton pulse height distribution using two different methods, viz. FERDOR and BUNKI. The details of various unfolding procedures used in this work are reported in this paper.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, , , , , ,