Article ID Journal Published Year Pages File Type
1830731 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2007 4 Pages PDF
Abstract

Pebble bed reactors (PBR) are characterized by multi-pass fuel systems in which spherical fuel pebbles are circulated through the core until they reach a proposed burnup limit. The fuel is assayed on-line to ensure that the burnup limit is not breached. However, random summing effects can impact the response of the burnup measurement system and result in distortions that degrade the accuracy of the assay results. Monte Carlo analysis was performed to estimate the magnitude and effect of random summing on the absolute and relative indicators that have been identified as usable in on-line assay. For a throughput rate of 105 counts/s and trapezoidal pulse shaping of the signals, the results show that absolute indicators suffer from severe distortions due to this effect. Relative indicators are found to be resistant to random summing with the deviation in the ratio of peak areas remaining less than 5–15% depending on pulse width.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Instrumentation
Authors
, ,