Abstract

Usage of electrodes made of glass with low bulk resistivity seems to be a promising way to adapt the Resistive Plate Chambers (RPC) to the high-rate environment of the upcoming CBM experiment. A pilot four-gap RPC sample with electrodes made of phosphate glass, which has bulk resistivity in the order of 1010Ωcm, has been studied with MIP beam for TOF applications. The tests have yielded satisfactory results: the efficiency remains above 95% and the time resolution stays within 120 ps up to the particle rate of 18 kHz/cm2. The increase in rate from 2.25 to 18 kHz/cm2 leads to an increase of estimated tails fraction in the time spectrum from 1.5% to 4%.