Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1831095 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2007 | 7 Pages |
In this paper, we report on new high-precision absolute distance measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distances were determined by counting the interference fringes produced while scanning the frequencies of the two chopped lasers. High-finesse Fabry–Perot interferometers were used to determine frequency changes during scanning. Dual lasers with oppositely scanning directions, combined with a multi-distance-measurement technique previously reported, were used to cancel drift errors and to suppress vibration effects and interference fringe uncertainties. Under realistic conditions, a precision about 0.2μm was achieved for a distance of 0.41 m. With a precision that exceeds requirements, the frequency scanned interferometry is a promising high-precision optical alignment technique for International Linear Collider silicon tracker detector.