Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1832476 | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | 2006 | 10 Pages |
The current generation of DEPMOSFET-based Active Pixel Sensor (APS) matrix devices has been developed to cope with the challenging requirements of the XEUS Wide Field Imager. The devices turned out to be a promising new imager concept for a variety of X-ray imaging applications. The devices combine excellent energy resolution, high-speed readout and low power consumption with the attractive feature of random accessibility of pixels. Sensor prototypes, built for row-wise readout, with 64×6464×64 pixels with a size of 75×75μm2 each have been produced at the MPI semiconductor laboratory in Munich, and their performance has been studied in detail. A spectroscopic resolution of 128 eV has been measured, the readout noise is as low as 3.5e- ENC. Here, measurements of the dependence of readout noise and spectroscopic resolution on the device temperature are presented.