Article ID Journal Published Year Pages File Type
183524 Electrochimica Acta 2015 6 Pages PDF
Abstract

The chemical imaging sensor was applied to in-situ pH imaging of the solution in the vicinity of a corroding surface of stainless steel under potentiostatic polarization. A test piece of polished stainless steel was placed on the sensing surface leaving a narrow gap filled with artificial seawater and the stainless steel was corroded under polarization. The pH images obtained during polarization showed correspondence between the region of lower pH and the site of corrosion. It was also found that the pH value in the gap became as low as 2 by polarization, which triggered corrosion.

Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Engineering (General)