Article ID Journal Published Year Pages File Type
1869579 Physics Procedia 2012 7 Pages PDF
Abstract

In the status of lacking research on response time of static var compensator (SVC), this paper established the controlled current source model which can achieve the same effect in response time and reactive compensation with the physical model of SVC by analyzing of characteristics in reactive power compensation and the response of the static var compensator (SVC) physical model. Through the time module in control signal of controlled current source, it can accurately calculate the response time of SVC. It tested the consistency of two models through the simulation of a rolling mill start experiment in PSCAD.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Physics and Astronomy (General)