Article ID Journal Published Year Pages File Type
1878858 Applied Radiation and Isotopes 2013 6 Pages PDF
Abstract

The half-lives of 221Fr, 217At, 213Bi, 213Po, and 209Pb were measured by means of an ion-implanted planar Si detector for alpha and beta particles emitted from weak 225Ac sources or from recoil sources, which were placed in a quasi-2π counting geometry. Recoil sources were prepared by collecting atoms from an open 225Ac source onto a glass substrate. The 221Fr and 213Bi half-lives were determined by following the alpha particle emission rate of recoil sources as a function of time. Similarly, the 209Pb half-life was determined from the beta particle count rate. The shorter half-lives of 217At and 213Po were deduced from delayed coincidence measurements on weak 225Ac sources using digital data acquisition in list mode. The resulting values: T1/2(221Fr)=4.806 (6) min, T1/2(217At)=32.8 (3) ms, T1/2(213Bi)=45.62 (6) min, T1/2(213Po)=3.708 (8) μs, and T1/2(209Pb)=3.232 (5) h were in agreement only with the best literature data.

► The decay series of 225Ac–213Bi is important for use in alpha-immunotherapy. ► The half-lives of 221Fr, 217At, 213Bi, 213Po, and 209Pb were measured. ► Used ion-implanted planar Si detector and digital data acquisition in list mode. ► The results agree with the best literature data only.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Radiation
Authors
, , , , , , , , , , ,