Abstract

The high-temperature ratio (HTR) method which exploits changes in the LiF:Mg,Ti glow-curve due to high-LET radiation, has been used for several years to estimate LET in an unknown radiation field. As TL efficiency is known to decrease after doses of densely ionizing radiation, a LET estimate is used to correct the TLD-measured values of dose. The HTR method is purely empirical and its general correctness is questionable. The validity of the HTR method was investigated by theoretical simulation of various mixed radiation fields.The LETeff values estimated with the HTR method for mixed radiation fields were found in general to be incorrect, in some cases underestimating the true values of dose-averaged LET by an order of magnitude. The method produced correct estimates of average LET only in cases of almost mono-energetic fields (i.e. in non-mixed radiation conditions). The value of LETeff found by the HTR method may therefore be treated as a qualitative indicator of increased LET, but not as a quantitative estimator of average LET.However, HTR-based correction of the TLD-measured dose value (HTR-B method) was found to be quite reliable. In all cases studied, application of this technique improved the result. Most of the measured doses fell within 10% of the true values. A further empirical improvement to the method is proposed. One may therefore recommend the HTR-B method to correct for decreased TL efficiency in mixed high-LET fields.

Related Topics
Physical Sciences and Engineering Physics and Astronomy Radiation
Authors
,