Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
1881740 | Radiation Measurements | 2009 | 4 Pages |
Abstract
This paper reports on studies of fast ions (mostly deuterons) emitted from an RPI (Rod-Plasma-Injector) plasma accelerator. The first aim was the verification of applicability of PM-355 track detectors for dosimetry of lower-energy (<200Â KeV) deuterons. The second aim was information about energy spectra of deuterons from RPI-IBIS device in different operational modes. Mass- and energy spectra of ions were investigated with a Thomson-analyzer and PM-355 detectors. On the recorded deuteron-parabolas we chose points, and from numbers of tracks we determined the deuteron energy distribution. In the slow-mode the energy distribution peak was observed at about 40Â keV, while the maximum energy amounted to about 150Â keV. Those measurements confirmed an influence of the initial gas-conditions on energy distributions of the deuteron streams. The results are of importance for plasma-physics and applications. Another result was the confirmation that PM-355 detectors might be used for accurate measurements of low-energy (<200Â keV) deuterons.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Radiation
Authors
E. Skladnik-Sadowska, K. Malinowski, M.J. Sadowski, K. Czaus,