Abstract
Although the prostate displacement of patients in the prone position is affected by respiration-induced motion, the effect of intrafractional prostate motion in the prone position during “simultaneous integrated boost intensity-modulated radiotherapy” (SIB-IMRT) is unclear. The purpose of this study was to evaluate the dosimetric effects of intrafractional motion on SIB-IMRT to a dominant intraprostatic lesion (IPL) using measured motion data of patients in a prone position, fixed with a thermoplastic shell. We obtained 2 orthogonal x-ray fluoroscopic images at the same moment every 0.2 seconds for 30 seconds before and after treatment, once weekly, from 7 patients with localized prostate cancer with detectable prostatic calcification. Prostate displacements in the left-right (LR), anteroposterior (AP), and superoinferior (SI) directions were calculated using the prostatic calcification as a fiducial marker. We defined the displacement between pretreatment and posttreatment as baseline drift (BD). An SIB-IMRT plan was generated in which each IPL + 3Â mm received a dose of 94.5Â Gy, whereas the remainder of the prostate + 7Â mm received a dose of 75.6Â Gy in 9 fields. A simulated plan of dose blurring was generated by the convolution of isocenter-shifted plans using measured motion data in 30 seconds and motion in 30 seconds + distance between pretreatment and posttreatment position (BD) for each of the 7 patients. The motion in 30 seconds mainly reflected respiration-induced motion. The mean displacements of BD were 1.4Â mm (â 3.1 to 8.2Â mm), â 2.2Â mm (â 9.1 to 1.5Â mm), and â 0.3Â mm (â 5.0 to 1.8Â mm) in the AP, SI, and LR directions, respectively. The differences in the target coverage with V90% of the IPL and V100% of the prostate between the simulated plan and original plan were â 3.9% to â 0.3% and â 0.6% to 1.1% for respiration-induced motion and 3.1% to â 67.8% and 3.6% to â 13.3% for BD with respiration-induced motion, respectively. The large motion of BD resulted in an inadequate coverage by the prescribed dose of the SIB-IMRT to the IPL. A 7-mm margin is recommended when real-time tracking techniques are not applied. The effect of respiration-induced motion was small, so long as a 3-mm margin was added.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Radiation
Authors
Itaru M.D., Ph.D., Takashi M.D., Ph.D., Tomohiro M.S., Masahiro Ph.D., Mitsuhiro Ph.D., Hajime Ph.D., Shinsuke R.T.T., Masahiro M.D., Ph.D.,