Article ID Journal Published Year Pages File Type
1884965 Medical Dosimetry 2015 4 Pages PDF
Abstract
A method is presented in which the couch position is predicted before the treatment instead of obtaining a reference position at the first treatment fraction. This prevents systematic differences in patient posture between preparation and treatment. In literature, only limited data are available on couch positioning. We position our patients at the planned couch position, allowing a small difference between skin marks and lasers, followed by online imaging. For a 3-month period, our standard deviations (mm) in couch position in the vertical, longitudinal, and lateral directions were head and neck-1.6, 2.8, and 2.5; thorax-2.9, 5.5, and 4.5; breast-3.0, 4.1, and 4.0; and pelvis-3.5, 4.0, and 4.7, respectively. We have improved the reproducibility of patient posture in our institute by using the predicted couch position. Our data may serve as a reference for other institutes because the couch position variation is less than that published in literature.
Keywords
Related Topics
Physical Sciences and Engineering Physics and Astronomy Radiation
Authors
, ,