The STARTRACK experimental set-up, mounted on the +50° beam line of the Tandem-Alpi particle accelerator of Legnaro National Laboratories, has been conceived to give an experimental basis to nanodosimetric calculations. STARTRACK is based on a detection system able to measure ionization cluster distributions in a 20 nm propane site with a resolution of one ionization. The experimental layout has been designed to minimize pile-up distortions. The background noise is filtered by off-line dedicated software. Electron cluster distribution of 20 MeV protons has been measured. Monte Carlo data and experimental data are pretty well consistent.
Keywords
Related Topics
Physical Sciences and Engineering
Physics and Astronomy
Radiation
Authors
V. Conte, L. De Nardo, P. Colautti, A. Ferretti, B. Grosswendt, M. Lombardi, M. Poggi, S. Canella, D. Moro, G. Tornielli,