This study was conducted to analyze the radiological impact in the experimental area of the Hard X-Ray beamline at Canadian Light Source under beam loss scenario during Top-up injection. The radiation doses were calculated using Monte Carlo code: FLUKA. The physical size, location, and material of the beamline components were adopted from the technical drawings and were incorporated in the FLUKA model. Three (03) beam loss scenarios were simulated: (i) Beam was miss-steered in the storage ring (ii) Beam hit misaligned components inside the ring and (iii) Beam was lost inside the primary optical enclosure (POE). Total ambient dose was calculated at several observation points for each scenario considering the injected beam as the primary source. The results and impacts were discussed.